Arguments
<NR3> is a floati
ng point number that specifies the minimum response time, in
seconds.
Examples
BUS:B1:MIL1553B:RESPONSET IME:MINIMUM 5.0E-6 specifies the minimum
responsetimetoavalidcommandreceivedtobe5.0microseconds.
BUS:B1:MIL1553B:RESPONSET IME:MINIMUM? might return
:BUS:B1:MIL1553B:RESPONSE TIME:MINIMUM 4.000E-6, indicating a
minimum response time of 4 microseconds.
BUS:B<x>:MIL1553B:SOUrce
This command sets or queries the source for the specified MIL-STD-1553 bus.
The bus is specified by x.
Conditions
Requires option SR-AERO.
Group
Bus
Syntax
BUS:B<x>:MIL1553B:SOUrce {CH<x>|Math<x>|REF<x>}
BUS:B<x>:MIL1553B:SOUrce?
Arguments
CH<x> specifies an analog channel as the source waveform for the MIL-STD-1553
bus.
Math<x> specifies a math waveform as the source waveform for the
MIL-STD-1553 bus.
REF<x> specifies a reference waveform as the source waveform for the
MIL-STD-1553 bus.
Examples
BUS:B1:MIL1553B:SOURCE CH1 sets channel 1 as the source for the
MIL-STD-1553 bus.
BUS:B1:MIL1553B:SOURCE? might r eturn :BUS:B1:MIL1553B:SO URCE
MATH2
indicating that the source is set to MATH2.
BUS:B<x>:MIL1553B:THRESHold
This command sets or querie
s the MIL-STD-1553 upper threshold f or the
specified bus. The bus is specified by x.