Commands listed in alphabetical order
POWer:POWer<
x>:SWITCHINGLOSS:GATESOurce
This command sets o r queries the gate voltage (V
g
) for the switching loss
measurement in the specied power measurement badge. The power measurement
badge is spec
ied by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:SWITCHINGLO SS:GATESOurce {CH<x> | MATH<x> |
REF<x>}
POWer:POWer<x>:SWITCHINGLO SS:GATESOurce?
Arguments
CH<x> = A channel specier; <x> is 1 through 8 and is limited by the number
of FlexChannels in your instrument.
MATH<x> = A math waveform specier; <x> is 1.
REF<x> = A reference waveform specier; <x> is 1.
Examples
POWer:POWer1:SWITCHINGLOSS :GATESOurce MATH1 sets the gate voltage
(Vg) for switching loss measurement of the speci ed power measurement source
as MATH1.
POWer:POWer2:SWITCHINGLOSS :VSOURce? might return MATH3 indicating
the gate voltage (Vg) for switching loss measurement of Power 2 power
measurement badge.
POWer:POWer<x>:SWITCHINGLOSS:ILEVELAbs
This command sets or queries the current level (Ton-Start & Stop) in absolute
units for s witching loss measurement in the specied power measurement badge.
The power measurement badge is specied by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:SWITCHINGLO SS:ILEVELAbs <NR1>
POWer:POWer<x>:SWITCHINGLO SS:ILEVELAbs?
MSO54, MSO56, MSO58, MSO58LP Programmer 2-587