Commands listed in alphabetical order
Related Commands
TRIGger:{A|B}
:BUS:B<x>:ETHERnet:CONDition
TRIGger:{A|B}:BUS:B<x>:ETHERnet:IPHeader:SOUrceaddr:VALue
TRIGger:{A|B}:BUS:B<x>:ETHERnet:IPHeader:DESTinationaddr:VALue
Arguments
<QString> is a quoted string of up to 8 characters where the allowable characters
are0,1,andX.Thebitsspecified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGGER:A:BUS:B1:ETHERNET: IPHEADER:PROTOCOL:VALUE "01010010"
would set the value to be used in the trigger to 01010010.
TRIGger:A:BUS:B1:ETHERnet: IPHeader:PROTOcol:VALue? might return
"XXXXXXXX".
TRIGger:{A|B}:BUS:B<x>:ETHERnet:IPHeader:SOUrceaddr:VA Lue
When the Ethernet trigger condition is set to IPHeader , this command specifies
the value of the 32-bit source address that is to be used in the trigger (along with
the destination address and protocol value). The IP source address is a standard
IP address such as 192.168.0.1. The default is all X’s (don’t care). The bus
number is specified by <x>.
Conditions
Requires the SR-ENET Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:ETH ERnet:IPHeader:
SOUrceaddr:VALue
<QString>
TRIGger:{A|B}:BUS:B<x>:ETH ERnet:IPHeader:SOUrceaddr:VALue?
Related Commands
TRIGger:{A|B}:BUS:B<x>:ETHERnet:CONDition
TRIGger:{A|B}:BUS:B<x>:ETHERnet:IPHeader:DESTinationaddr:VALue
TRIGger:{A|B}:BUS:B<x>:ETHERnet:IPHeader:PROTOcol:VALue
Arguments
<QString> is a quoted string of up to 32 characters where the allowable
characters are 0, 1, and X. The bits specified in the quoted string replace the least
significant bits, leaving any unspecified upper bits unchanged.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-785