Commands listed in alphabetical order
Examples
TRIGGER:A:BUS
:B1:CAN:DATA:VALUE "1011"
sets the CAN data value to
1011.
TRIGGER:A:BU
S:B1:CAN:DATA:VALUE?
might return
:TRIGGER:A:BUS:B1:CAN:DATA :VALUE "XXXXXXXX" indicating
the data valule is set to XXX XXXXX.
TRIGger:{A
|B}:BUS:B<x>:CAN:ERRType
This command sets or queries the type of error condition for a CAN bus to
triggering on. The bus number is specied by x. The trigger condition must be
set to ERR
or.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:CAN :ERRType
{ACKMISS|BITSTUFFing|FORMERRor|ANYERRor}
TRIGger:{A|B}:BUS:B<x>:CAN :ERRType?
Arguments
ACKMISS species triggering on a missing ACK eld.
BITSTUFFing spec ies triggering on a bit stufng error.
FORMERRor species triggering on a CAN FD form error. To use this option, the
CAN standard must be set to FDISO or FDNONISO.
ANYERRor species triggering on any error type.
Examples
TRIGGER:A:BUS:B1:CAN:ERRTY PE ACKMISS species triggering on any
missing A CK elds.
TRIGGER:A:BUS:B1:CAN:ERRTY PE? might return ANYERROR, indicating that
the bus is triggering on all error types.
TRIGger:{A|B}:BUS:B<x>:CAN:FD:BRSBit
This command sets or queries the value of the bit rate switch bit (BRS bit) for a
CAN bus to triggering on. The bus number is specied
by x. The trigger condition
must be set to FDBITS, and the CAN standard must be FDISO or FDNONISO.
Conditions
Requires the SR-AERO Triggering and Analysis application.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-775

Table of Contents

Other manuals for Tektronix MSO58