Commands listed in alphabetical order
TRIGger:{A|B
}:BUS:B<x>:MIL1553B:TIMe:QUALifier
This command sets or queries the qualifier to be used when triggering on response
time / inter message gap time for a MIL-STD-1553 bus. The bus number is
specified by x
. The trigger condition must be set to TIMe.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:MI L1553B:TIMe:QUALifier
{LESSthan|MOREthan|INrange|OUTrange}
TRIGger:{A|B}:BUS:B<x>:MI L1553B:TIMe:QUALifier?
Related Commands
TRIGger:{A|B}:BUS:B<x>:MIL1553B:TIMe:LESSLimit, TRIGger:{A|B}:BUS:
B<x>:MIL1553B:TIMe:MORELimit
Arguments
Arguments are the available comparison qualifiers.
Examples
TRIGGER:A:BUS:B1:MIL1553B :TIME:QUALIFIER LESSTHAN sets the time
comparison qualifier to less than.
TRIGGER:A:BUS:B1:MIL1553B :TIME:QUALIFIER? might return
OUTRANGE, indicating that the qualifier is set to o ut-of-range comparison.
TRIGger:{A|B}:BUS:B<x>:PARallel:DATa:VA Lue
This command specifies the binary data string used for a Parallel Bus trigger.
The bus number is specified by <x>.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:PA Rallel:DATa:VALue <QStrin g>
TRIGger:{A|B}:BUS:B<x>:PA Rallel:DATa:VALue?
Arguments
<QString> is the binary data string used for a Parallel Bus trigger.
Examples
TRIGger:A:BUS:B1:PARallel :DATa:VALue "11001101" sets the data
value to 11001101.