EasyManua.ls Logo

Tektronix MSO58 - DISplay:GLObal:PLOT<x>:STATE; DISplay:GLObal:REF<x>:STATE

Tektronix MSO58
1026 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commands listed in alphabetical order
DISplay:GLOb
al:PLOT<x>:STATE
This command sets o r queries the global state (display mode On or Off) of the
specified time trend plot. Setting this value true (On or NR1 ≠ 0)turnsonthe
source in the
waveform view. Setting this value false (Off or NR1 = 0 ) turns off
the source in the waveform view. This command only works if the specified
plot is added already.
Group
Display Control
Syntax
DISplay:GLObal:PLOT<x>:ST ATE {<NR1>|OFF|ON}
Arguments
<NR1> = 0 disables the display of the specified plot; any other value enables
display of the plot.
ON enables display of the specified plot.
OFF disables display of the specified plot.
Examples
DISplay:GLObal:PLOT1:STAT E ON displays plot 1.
DISplay:GLObal:PLOT1:STAT E? might return
:DISPLAY:GLOBAL:PLOT1:STA TE 1 indicating plot 1 is displayed.
DISplay:GLObal:REF<x>:STATE
this command sets or queries the global state (d
isplay mode On or Off) of the
specified reference waveform. Setting this v alue true (On or NR1 ≠ 0)turnson
the source in the waveform view. Setting this value false (Off or NR1 = 0 ) turns
off the source in the waveform view. This command only works if the specified
reference waveform is added already.
Group
Display Control
Syntax
DISplay:GLObal:REF<x>:STA TE {<NR1>|OFF|ON}
Arguments
<NR1> = 0 disables the display of the specified reference; any other value enables
display of the reference.
ON enables display of the specified reference.
OFF disables display of the specified reference.
2-230 MSO54, MSO56, MSO58, MSO58LP Programmer