Commands listed in alphabetical order
MEASUrement:
MEAS<x>:IDLETime
This command sets or queries the idle time for the measurement when the
measurement type is burst width. Measurements are specied by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:IDLETi me <NR3>
MEASUrement:MEAS<x>:IDLETi me?
Arguments
<NR3> is the idle time.
Examples
MEASUrement:MEAS1:IDLETime 40.0E-6 sets the idle time to 40.0 μs.
MEASUrement:MEAS1:IDLETime ? might return
:MEASUREMENT:MEAS1:IDLETIM E 50.0000E-6 indicating the idle time
is 50.0 μs.
MEASUrement:MEAS<x>:JITTERSummary:DCD
This command sets or queries whether DCD is included in the jitter summary for
the measurement. Measurements are specied by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:JITTER Summary:DCD {0|1}
MEASUrement:MEAS<x>:JITTER Summary:DCD?
Arguments
1 add the DCD measurement as part of jitter summary.
0 do not add the DCD measurement as part o f jitter summary.
Examples
MEASUrement:MEAS1:JITTERSu mmary:DCD 0 species that the DCD
measurement is not part of the jitter summary.
MEASUrement:MEAS1:JITTERSu mmary:DCD? might return
:MEASUREMENT:MEAS4:JITTERS UMMARY:DCD 1 indicating the DCD
measurement is part of the jitter summary.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-457