Commands listed in alphabetical order
Examples
TRIGger:A:BUS
:B1:USB:SPLit:SE:VALue ISOEND
specifies to trigger on
the ISOEND split transaction value.
TRIGger:A:BUS:B1:USB:SPLi t:SE:VALue? might return FULLSPEED.
TRIGger:{A|B}:BUS:B<x>:USB:TOKENType
This command specifies the token type for the USB trigger. The bu
s number is
specified by <x>.
Conditions
Requires the SR-USB2 Serial Triggering and Analysis Appli
cation.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:US B:TOKENType {ANY|SOF|OUT| IN|SETUP}
TRIGger:{A|B}:BUS:B<x>:US B:TOKENType?
Related Commands
TRIGger:{A|B}:BUS:B<x>:USB:CONDition
Arguments
ANY indicates any of the token types.
SOF indicates a SOF (start-of-frame) token type
OUT indicates an OUT token type.
IN indicates an IN token type.
SETUP indicates a SETUP token type.
Examples
TRIGGER:A:BUS:B1:USB:TOKE NTYPE SETUP sets the token type to SETUP.
TRIGGER:A:BUS:B1:USB:TOKE NTYPE? might return
:TRIGGER:A:BUS:B1:USB:TOK ENTYPE SOF if the token type is SOF.
TRIGger:{A|B}:BUS:SOUrce
This command sets or queries the source bus for a bus trigger.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:SOUrce B<x>
TRIGger:{A|B}:BUS:SOUrce?
2-848 MSO54, MSO56, MSO58, MSO58LP Programmer