Commands listed in alphabetical order
Related Commands
SEARCH:SEARCH
<x>:TRIGger:A:BUS:ETHERnet:CONDition
SEARCH:SEARCH<x>:TRIGger:A:BUS:ETHERnet:DATa:VALue
SEARCH:SEARCH<x>:TRIGger:A:BUS:ETHERnet:DATa:SIZe
Arguments
<NR1> is a
n integer whose minimum and default values are -1 (don't care) and
maximum is 1,499.
Examples
SEARCH
:SEARCH1:TRIGGER:A:BUS:ETH ERNET:DATA:OFFSEt 36
sets the
data offset to 36 bytes.
SEARCH:SEARCH1:TRIGGER:A:B US:ETHERNET:DATA:OFFSET? might return
-1, indicating that the data offset value is the default value, -1, meaning "don’t
care".
SEARCH:SEARCH<x>:TRIGger:A:BUS:ETHERnet:DATa:QUALier
This command species the qualier to be used when searching on an Ethernet
bus signal. The search condition must be set to
DATa. The search number is
specied by <x>.
Conditions
Requires the SR-ENET Triggering and Analysis application.
Group
Search and Mark
Syntax
SEARCH:SEARCH<x>:TRIGger:A :BUS:ETHERnet:DATa:QUALifier
{LESSthan|MOREthan|EQual|U NEQual|LESSEQual|MOREEQual|
INrange|OUTrange}
SEARCH:SEARCH<x>:TRIGger:A :BUS:ETHERnet:DATa:QUALifier?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:ETHERnet:CONDition
Arguments
LESSthan sets the qualier to less than.
MOREthan sets the qualier to greater than.
EQual sets the qualier to equal.
UNEQual sets the qualier to not equal.
LESSEQual sets the qualier to less than or equal.
MOREEQual sets the qualier to greater than or equal.