Commands listed in alphabetical order
Syntax
TRIGger:{A|B}
:BUS:B<x>:MIL1553B:COMMAND:T RBit {RX|TX|X}
TRIGger:{A|B}:BUS:B<x>:MI L1553B:COMMAND:TRBit?
Arguments
RX filters command words to only match those that are receive packets.
TX filters command words to only match those that are transmit packets.
X disables filtering of command words on the R/T bit.
Examples
TRIGGER:A:BUS:B1:MIL1553B :COMMAND:TRBIT TX specifies filtering
command words for only transmit messages.
TRIGGER:A:BUS:B1:MIL1553B :COMMAND:TRBIT? might return X, indicating
that command words are not being fi ltered based on the R/T bit value.
TRIGger:{A|B}:BUS:B<x>:MIL1553B:CONDition
This command sets or queries the field or condition for a MIL-STD-1553 bus to
trigger on. The b us number is specified by x.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:MI L1553B:CONDition
{SYNC|COMMAND|STATus|DATA |TIMe|ERRor}
TRIGger:{A|B}:BUS:B<x>:MI L1553B:CONDition?
Arguments
SYNC specifies triggering on the s ync pulse of any word.
COMMAND specifies triggering on a matching command word.
STATus specifies triggering on a matching status word.
DATA specifies triggering on a matching data word.
TIMe specifies triggering on the response time or intermessage gap between words.
ERRor specifies triggering on a specified error condition.
Examples
TRIGGER:A:BUS:B1:MIL1553B :CONDITION DATA specifies finding matching
data word(s).
TRIGGER:A:BUS:B1:MIL1553B :CONDITION? might return SYNC, indicating
that the bus is triggering on sync pulses found in any word.
2-818 MSO54, MSO56, MSO58, MSO58LP Programmer