Commands listed in alphabetical order
MEASUrement:R
EF1:REFLevels:ABSolute:FALLL ow?
might return
:MEASUREMENT:REF1:REFLEVE LS:ABSOLUTE:FALLLOW -1.00 00 indicating
the low reference level is -1.0 V.
MEASUrement
:REF<x>:REFLevels:ABSolute:FALLMid
This command sets or queries the value us ed as the mid reference level of the
falling edge when the measurement's ref level method is set to absolute.
Group
Measurement
Syntax
MEASUrement:REF<x>:REFLev els:ABSolute:FALLMid <NR3>
MEASUrement:REF<x>:REFLev els:ABSolute:FALLMid?
Arguments
<NR3> is the value used as the mid reference level of the falling edge when the
measurement's ref level method is set to absolute.
Examples
MEASUrement:REF1:REFLevel s:ABSolute:FALLMid 50.0E- 3 sets the
mid refe rence level to 50.0 mV.
MEASUrement:REF1:REFLevel s:ABSolute:FALLMid? might return
:MEASUREMENT:REF1:REFLEVE LS:ABSOLUTE:FALLMID 0.0E+ 0 indicating
the reference level is 0.0 V.
MEASUrement:REF<x>:REFLevels:ABSolute:HYSTeresis
This command sets or queries the value of the hysteresis of the reference level
when the measurement's ref level m ethod is set to absolute.
Group
Measurement
Syntax
MEASUrement:REF<x>:REFLev els:ABSolute:HYSTeresis <NR3>
MEASUrement:REF<x>:REFLev els:ABSolute:HYSTeresis?
Arguments
<NR3> is the value of the hysteresis of the reference level when the measurement's
ref level method is set to absolute.
Examples
MEASUrement:REF1:REFLevel s:ABSolute:HYSTeresis 20. 0E-3 sets the
hysteresis to 20.0 mV.
2-508 MSO54, MSO56, MSO58, MSO58LP Programmer