Commands listed in alphabetical order
Conditions
Requires the SR
-AUTO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:LI N:CONDition
{SYNCfield|IDentifier|DAT a|IDANDDATA|WAKEup|SLEEP|ERRor}
TRIGger:{A|B}:BUS:B<x>:LI N:CONDition?
Arguments
SYNCfield sets the LIN trigger condition to sync eld.
IDentifier sets the LIN trigger condition to identier.
DATa sets the LIN trigger condition to data.
IDANDDATA sets the LIN trigger condition to id and data.
WAKEup sets the LIN trigger condition to wake up.
SLEEP sets the LIN trigger condition to sleep.
ERRor sets the LIN trigger condition to error.
Examples
TRIGGER:A:BUS:B1:LIN:COND ITION ERROR sets the LIN trigger condition
to error.
TRIGGER:A:BUS:B1:LIN:COND ITION? might return
TRIGGER:A:BUS:B1:LIN:COND ITION SYNCFIELD indicating the LIN trigger
condition is sync eld.
TRIGger:{A|B}:BUS:B<x>:LIN:DATa:HIVALue
This command species the high data value string used for a LIN bus trigger
when the trigger condition is DATA o r IDANDDATA and the data qualier is
INRANGE or OUTRANGE. The bus number is specied by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:LI N:DATa:HIVALue <QString>
TRIGger:{A|B}:BUS:B<x>:LI N:DATa:HIVALue?