Commands listed in alphabetical order
Group
Measurement
Syntax
MEASUrement:REF<x>:REFLev els:PERCent:HYSTeresis <NR3>
MEASUrement:REF<x>:REFLev els:PERCent:HYSTeresis?
Arguments
<NR3> is the percentage used to calculate the hysteresis of the reference level.
Examples
MEASUrement:REF1:REFLevel s:PERCent:HYSTeresis 2 sets the hysteresis
to 2%.
MEASUrement:REF1:REFLevel s:PERCent:HYSTeresis? might return
:MEASUREMENT:REF1:REFLEVE LS:PERCENT:HYSTERESIS 5.0 000
indicating the hysteresis is 5%.
MEASUrement:REF<x>:REFLevels:PERCent:RISEHigh
This command sets or queries the percentage (where 100% is equal to TOP and
0% is equal to BASE) used to calculate the high reference level of the rising edge
when the measurement's ref level method is set to percent.
Group
Measurement
Syntax
MEASUrement:REF<x>:REFLev els:PERCent:RISEHigh <NR3>
MEASUrement:REF<x>:REFLev els:PERCent:RISEHigh?
Arguments
<NR3> is the percentage used to calculate the high reference level of the rising
edge
Examples
MEASUrement:REF1:REFLevel s:PERCent:RISEHigh 95 sets the reference
level to 95%.
MEASUrement:REF1:REFLevel s:PERCent:RISEHigh? might return
:MEASUREMENT:REF1:REFLEVE LS:PERCENT:RISEHIGH 90.00 00 indicating
the reference level is 90%.
MEASUrement:REF<x>:REFLevels:PERCent:RISELow
This command sets or queries the percentage (where 100% is equal to TOP and
0% is equal to BASE) used to calculate the low reference level of the rising edge
when the measurement's ref level method is set to percent.
2-514 MSO54, MSO56, MSO58, MSO58LP Programmer