EasyManua.ls Logo

Tektronix MSO58

Tektronix MSO58
1026 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commands listed in alphabetical order
Examples
POWer:POWer1:
SWITCHINGRIPPLE:SFREQuency 60000
sets the frequency
present for line ripple measurement as 60000 Hz.
POWer:POWer<x>:TYPe
This command sets or quer ies the measurement type for the specied power
measurement badge. The power m easurement badge is specied by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:TYPe <Measurement Type>
POWer:POWer<x>:TYPe?
Arguments
<Measurement Type> = SOA | SWITCHINGLOss | CYCLEAmp |
CYCLEMAx | CYCLEMIn | CYCLEPKpk | SWITCHINGRIpple | LINERIpple
| NDUTYCycle | NPULSEWidth | PDUTYCycle | PPULSEWidth | DIDT |
DVDT | FREQuency | HARMonics | CYCLETop | CYCLEBase | PERIod |
POWERQUALity
Examples
POWer:POWer1:TYPe POWERQUALITY adds Power1 measurement badge and
selects the Power Quality measurement.
POWERTABle:ADDNew (No Query F orm)
This command adds the power harmonics table. The power measurement badge
is specied by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWERTABle:ADDNew TABLE<x>
Arguments
<x> must be greater than or equal to one.
Examples
POWTABle:ADDNew "TABLE1" adds power harmonics table.