Commands listed in alphabetical order
Syntax
TRIGger:{A|B}
:BUS:B<x>:USB:DATa:HIVALue <QString>
TRIGger:{A|B}:BUS:B<x>:USB :DATa:HIVALue?
Related Commands
TRIGger:{A|B}:BUS:B<x>:USB:CONDition,
TRIGger:{A|B}:BUS:B<x>:USB:DATa:VALue
Arguments
<QString> within the range 00000000 to 11111111 (00 hex to FF hex).
Examples
TRIGGER:A:BUS:B1:USB:DATA: HIVALUE "00001000" sets the upper limit
to binary 00001000 (08 hex).
TRIGGER:A:BUS:B1:USB:DATA: HIVALUE? might return
:TRIGGER:A:BUS:B1:USB:DATA :HIVALUE "01111111",which
indicates that the upper limit is 0
1111111 (7F hex).
TRIGger:{A|B}:BUS:B<x>:USB:DATa:OFFSet
This command specifi es the data offset in bytes to trigger on. The bus number is
specified by <x>.
Conditions
Requires the SR-USB2 Serial Triggering and Analysis Application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:USB :DATa:OFFSet <NR1>
TRIGger:{A|B}:BUS:B<x>:USB :DATa:OFFSet?
Related Commands
TRIGger:{A|B}:BUS:B<x>:USB:CONDition
Arguments
<NR1> is number in the range 0 to 1024.
Examples
TRIGGER:A:BUS:B1:USB:DATA: OFFSET 36 sets the data offset to 36.
TRIGGER:A:BUS:B1:USB:DATA: OFFSET? might return
:TRIGGER:A:BUS:B1:USB:DATA :OFFSET 0, indicating that the
data offset is the default value, 0.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-837