EasyManua.ls Logo

Tektronix MSO58 - TRIGger:{A|B}:BUS:B<x>:ETHERnet:CONDition

Tektronix MSO58
1026 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commands listed in alphabetical order
TRIGger:{A|B
}:BUS:B<x>:ETHERnet:CONDition
This command specifies a field or condition within an Ethernet frame to trigger
on. The bus number is specified by <x>.
Conditions
Requires the SR-ENET Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:ETH ERnet:CONDition
{SFD|MACADDRess|MACLENgth| IPHeader|TCPHeader|DATa|EOP|
IDLe|FCSError|QTAG}
TRIGger:{A|B}:BUS:B<x>:ETH ERnet:CONDition?
Related Commands
Most of the other TRIGger: A:BUS:B<x>:ETHER net
commands are impacted
by the setting of this command.
Arguments
SFD — Start of frame delimiter.
MACADDRess — MAC addresses field.
MACLENgth —MAC
length/type field.
IPHeader —IPheaderfield. This argument is only available when PROTOCOL
is set to IPv4.
TCPHeader — TCP header field. This argument is only available when
PROTOCOL is s
et to IPv4.
DATa — TCP/IPv4 or MAC protocol client data field. If the protocol is set to
OTHER, then
DATa refers to the M AC client data.
EOP — End of Packet field.
IDLe —Idlefield.
FCSError — Frame Check Sequence Error (CRC) field.
QTAG — IEEE 802.1Q (VLAN) control information field. In order to use QTAG as
a trigger condition, the frame type must be set to QTAG ).
Examples
TRIGger:A:BUS:B1:ETHERnet: CONDition MACADDRess sets the trigger
field to
MACADDRess.
TRIGger:A:BUS:B1:ETHERnet: CONDition? might return DATA.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-779