Commands listed in alphabetical order
POWer:POWer<
x>:SOA:ISOURce
This command sets or queries the current source for SOA measurement in the
specied power measurement badge. The power measurement badge is specied
by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:SOA:ISOURc e {CH<x> | MATH<x> | REF<x>}
POWer:POWer<x>:SOA:ISOURc e?
Arguments
CH<x> = A channel specier; <x> is 1 through 8 and is limited by the number
of FlexChannels in your instrument.
MATH<x> = A math waveform specier; <x> is 1.
REF<x> = A reference waveform specier; <x> is 1.
Examples
POWer:POWer1:SOA:ISOURce CH2 sets the current source for SOA
measurement as channel 2.
POWer:POWer<x>:SOA:POINT
This command sets or queries the Y co-ordinate va lue for SOA mask.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:SOA:POINT <QString> <NR1>
POWer:POWer<x>:SOA:POINT <QString>?
Arguments
<QString> = 1Y | 2Y | 3Y | 4Y | 5Y | 6Y | 7Y | 8Y | 9Y | 10Y | 11Y | 12Y | 13Y
| 14Y | 15Y | 16Y | 17Y | 18Y | 19Y | 20Y | 21Y | 22Y | 23Y | 24Y | 25Y | 26Y
| 27Y | 28Y | 29Y | 30Y | 31Y | 32Y
<NR1> ranges from –5000 to 5000