Commands listed in alphabetical order
Syntax
TRIGger:{A|B}
:BUS:B<x>:CAN:CONDition
{SOF|FRAMEtype|IDentifier| DATa|IDANDDATA|EOF|ERRor|FDBITS}
TRIGger:{A|B}:BUS:B<x>:CAN :CONDition?
Arguments
SOF enables triggering on the start of frame.
FDBITS enables triggering on the values of the BRS and ESI bits in an FD packet.
FRAMEtype enables triggering on the type of frame.
IDentifier enables triggering on a matching identifier.
DATa enables triggering on matching data.
IDANDDATA enables triggering on a matching identifier and matching data.
EOF enables triggering on the end of frame.
ERRor enables triggering on a specified error condition.
Examples
TRIGGER:A:BUS:B1:CAN:CONDI TION? might return
:TRIGGER:A:BUS:B1:CAN:CONDITION EOF indicating an end of file
condition.
TRIGGER:A:BUS:B1:CAN:CONDI TION DATA enables triggering on matching
CAN data.
TRIGger:{A|B}:BUS:B<x>:CAN:DATa:DIRection
This command sets the data direction (read, write or “nocare”) to be used to
search on a CAN bus signal. The trigge
r condition must be set to IDentifier (using
TRIGger:{A|B}:BUS:B<x>:CAN:CONDition). The bus number is specified
by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:CAN :DATa:DIRection
{READ|WRITE|NOCARE}
TRIGger:{A|B}:BUS:B<x>:CAN :DATa:DIRection?
Arguments
READ sets the CAN data direction to READ.
WRITE sets the CAN data direction to WRITE.
NOCARE sets the CAN d ata direction to e ither.