Commands listed in alphabetical order
Arguments
CH<x> species
an analog channel as the clock source. Number of channels
depends on instrument conguration.
CH<x>_D<y> species a digital channel as the clock source. Number of channels
depends on instrument conguration.
Examples
TRIGger:A:LOGIc:INPut:CLOC k:SOUrce CH3 sets the clock source to
channel 3.
TRIGger:A:LOGIc:INPut:CLOC k:SOUrce? might return
:TRIGGER:A:LOGIC:INPUT:CLO CK:SOURCE CH3 indicating the clock source
is set to channel 3.
TRIGger:{A|B}:LOGIc:POLarity
This command sets or queries the polarity for the clock channel when Use Clock
Edge is set to Yes for Logic trigger type.
Group
Trigger
Syntax
TRIGger:{A|B}:LOGIc:POLari ty {POSitive|NEGative|EITher }
TRIGger:{A|B}:LOGIc:POLari ty?
Arguments
NEGative species negative polarity.
POSITIVe species positive polarity.
EITher species either polarity.
Examples
TRIGger
:A:LOGIc:POLarity EITHER
sets the polarity to either positive or
negative.
TRIGger:A:LOGIc:POLarity? might return :TRIGGER:A:LOGIC:POLARITY
POSITIVE
indicating the polarity is set to positive.
TRIGger:{A|B}:LOGIc:USECLockedge
This command species whether or not Logic trigger type uses clock source.
Group
Trigger
Syntax
TRIGger:{A|B}:LOGIc:USECLo ckedge {OFF|ON|0|1}
TRIGger:{A|B}:LOGIc:USECLo ckedge?