EasyManua.ls Logo

Dell PowerConnect 6224 - Lldp Notification-Interval

Dell PowerConnect 6224
1372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LLDP Commands 411
Example
The following example displays how to enable remote data change
notifications.
console(config-if-1/g3)#lldp notification
lldp notification-interval
Use the lldp notification-interval command in Global Configuration mode
to limit how frequently remote data change notifications are sent. To return
the notification interval to the factory default, use the no form of this
command.
Syntax
lldp notification-interval
interval
no lldp notification-interval
interval — The smallest interval in seconds at which to send remote data
change notifications. (Range: 5–3600 seconds)
Default Configuration
The default value is 5 seconds.
Command Mode
Global Configuration mode
User Guidelines
This command has no user guidelines.
Example
The following example displays how to set the interval value to 10 seconds.
console(config)#lldp notification-interval 10