Command groups
Table 2-34: Power commands (cont.)
Command Description
POWer:POWer<x>:RESUlts:
ALLAcqs:STDDev?
Queries the standard deviation value of all acquisitions for the measurement parameter in
the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:F1MAG?
Queries the first harmonics magnitude value for the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:F3MAG?
Queries the third harmonics magnitude value for the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:FREQUENCY?
Queries the fundamental frequency for the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:IRMS?
Queries the RMS current value for the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:MAXimum?
Queries the maximum value of the current acquisition for the measurement parameter in
the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:MEAN?
Queries the mean value of the current acquisition for the measurement parameter in the
specified power m easurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:MINimum?
Queries the minimum value of the current acquisition for the measurement parameter in the
specified power m easurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:PK2PK?
Queries the peak-to-peak value o f the current acquisition for the measurement parameter in
the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:POHCL?
Queries the limit of partial odd harmonic current for the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:POHCM?
Queries the measured value of partial odd harmonic current for the specified power
measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:POHCS?
Queries the status of partial odd harmonic current for the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:POPUlation?
Queries the population (number of complete cycles) of the current acquisition for the
measurement parameter in the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:RMS?
Queries the RMS value of the source selected for the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:STATUS?
Queries the status of the measurement for the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:STDDev?
Queries the standard deviation value of the current acquisition for the measurement parameter
in the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:THDF?
Queries the total harmonic distortion (fundamental) value for the specified power measurement
badge.
POWer:POWer<x>:RESUlts:
CURRentacq:THDR?
Queries the total harmonic distortion (RMS) value for the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:TRPWR?
Queries the true power value for the specified power measurement badge.
POWer:POWer<x>:RESUlts:
CURRentacq:VRMS?
Queries the RMS voltage value for the specified power measurement badge.
POWer:POWer<x>:SOA:ISOURce Sets or queries the current source for SOA measurement in the specified power measurement
badge.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-59