CHAPTER 7-2: VBAT Domain(A)
FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E 251
Interface circuit type 2
Figure 2-3 Configuration of Interface Circuit Type 2
Use this circuit type if the register has to retain data even when the VCC power supply is off.
Table 2-3 Behavior of Register of Interface Circuit Type 2
Behavior of register/buffer
Initialization of register
Initialization of register by the power-on signal of the VBAT Domain
Initialization of register by the reset signal of the Always-on Domain
For reset factors, see the chapter RTC Count Block.
Data in the buffer is read to the bus.
Data is written to the buffer.
Data is transferred from the register to the buffer.
Data is transferred from the buffer to the register.
Interface circuit type 3
Figure 2-4 Configuration of Interface Circuit Type 3
Use this circuit type if the register has to retain data even when the VCC power supply is off.
Table 2-4 Behavior of Register of Interface Circuit Type 3
Behavior of Register/Buffer
Initialization of register
Initialization of register by the power-on signal of the VBAT Domain
Initialization of register by the reset signal of the Always-on Domain
Initialization of register by RTC reset.
Data in the buffer is read to the bus.
Data is written to the buffer.
Data is transferred from the register to the buffer.
Data is transferred from the buffer to the register.