CHAPTER 8: Interrupts
430 FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E
4.38 IRQ119 Batch Read Register (IRQ119MON)
The IRQ119 Batch Read Register (IRQ119MON) can read out the interrupt (Flash I/F interrupt) assigned
to exception no. 135.
Register configuration
bit
31
8
Field
Reserved
Attribute
R
Initial value
0x000000
bit
7
6
5
4
3
2
1
0
Field
Reserved
FLINT
Attribute
R
R
Initial value
0000000
0
Register function
[bit31:1] Reserved: Reserved bits
A reserved bit reads 0.
[bit0] FLINT
Value
Description
0
There is no interrupt request of the Flash I/F.
1
An interrupt request of the Flash I/F has been made.