CHAPTER 15: SD Card Interface
FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E 875
2.27 Force Event Register for Auto CMD Error Status
The Force Event Register for Auto CMD Error Status is not a physically implemented register, but is an
address to which the settings of the Auto CMD Error Status Register can be written.
D15 D08
D07
D06 D05
D04
D03
D02
D01
D00
Rsvd
Force Event for Command Not
Issued by Auto CMD12 Error
Rsvd
Force Event for Auto CMD Index
Error
Force Event for Auto CMD End
Bit Error
Force Event for Auto CMD CRC
Error
Force Event for Auto CMD
Timeout Error
Force Event for Auto CMD12 not
executed
For details of this register, refer to SD Specifications Part A2.