CHAPTER 8: Interrupts
FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E 415
4.25 IRQ078/113 Batch Read Register (IRQxxxMON)
The IRQ078MON and IRQ113MON Registers can read out at once the interrupts (DRQ interrupts of
endpoint 0 to endpoint 5 of USB ch.0, and DRQ interrupts of endpoint 0 to endpoint 5 of USB ch.1,
HDMI-CEC remote control reception ch.0 interrupt) assigned to exception no. 94 and no. 129
respectively.
Register configuration
Register function
[bit31:6] Reserved: Reserved bits
A reserved bit reads 0.
[bit5] RCEC0INT
There is no HDMI-CEC remote control reception ch.0 interrupt.
A HDMI-CEC remote control reception ch.0 interrupt has been made.
There is no endpoint 5 DRQ interrupt request of the USB channel corresponding
to the IRQxxxMON Register.
An endpoint 5 DRQ interrupt request of the USB channel corresponding to the
IRQxxxMON Register has been made.
There is no endpoint 4 DRQ interrupt request of the USB channel corresponding
to the IRQxxxMON Register.
An endpoint 4 DRQ interrupt request of the USB channel corresponding to the
IRQxxxMON Register has been made.
There is no endpoint 3 DRQ interrupt request of the USB channel corresponding
to the IRQxxxMON Register.
An endpoint 3 DRQ interrupt request of the USB channel corresponding to the
IRQxxxMON Register has been made.
There is no endpoint 2 DRQ interrupt request of the USB channel corresponding
to the IRQxxxMON Register.
An endpoint 2 DRQ interrupt request of the USB channel corresponding to the
IRQxxxMON Register has been made.
There is no endpoint 1 DRQ interrupt request of the USB channel corresponding
to the IRQxxxMON Register.
An endpoint 1 DRQ interrupt request of the USB channel corresponding to the
IRQxxxMON Register has been made.
RCEC0INT only exists in IRQ113MON. It is reserved in IRQ078MON.
See Table 3-1 and Table 3-2 for the relationship between exception no. and interrupt.