CHAPTER 8: Interrupts
418 FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E
4.27 IRQ080 Batch Read Register (IRQ080MON)
The IRQ080MON Register can read out at once the interrupts (interrupts of CAN ch.0 ) assigned to
exception no. 96 respectively.
Register configuration
bit
31
8
Field
Reserved
Attribute
R
Initial value
0x000000
bit
7
6
5
4
3
2
1
0
Field
Reserved
CANINT
Attribute
R
R
Initial value
0000000
0
Register function
[bit31:1] Reserved: Reserved bits
A reserved bit reads 0.
[bit0] CANINT
Value
Description
0
There is no interrupt request of the CAN channel corresponding to the IRQxxxMON Register.
1
An interrupt request of the CAN channel corresponding to the IRQxxxMON Register has been
made.