CHAPTER 8: Interrupts
428 FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E
4.36 IRQ117 Batch Read Register (IRQ117MON)
The IRQ117MON Register can read out at once the interrupts (interrupts of I
2
S, Programmable CRC,
Smart Card Interface) assigned to exception no. 133.
Register configuration
bit
31
8
Field
Reserved
Attribute
R
Initial value
0x000000
bit
7
6
5
4
3
2
1
0
Field
Reserved
ICC1INT
ICC0INT
I2S1INT
PRGCRC
I2SINT
Attribute
R
R
R
R
R
R
Initial value
000
0
0
0
0
0
Register function
[bit31:5] Reserved: Reserved bits
A reserved bit reads 0.
[bit4] ICC1INT
Value
Description
0
There is no Smart Card Interface ch.1 interrupt.
1
An interrupt request of Smart Card Interface ch.1 has been made.
[bit3] ICC0INT
Value
Description
0
There is no Smart Card Interface ch.0 interrupt.
1
An interrupt request of Smart Card Interface ch.0 has been made.
[bit2] I2S1INT
Value
Description
0
There is no I
2
S ch.1 interrupt.
1
An interrupt request of I
2
S ch.1 has been made.
[bit1] PRGCRC
Value
Description
0
There is no programmable CRC interrupt.
1
An interrupt request of programmable CRC has been made.
[bit0] I2SINT
Value
Description
0
There is no I
2
S ch.0 interrupt.
1
An interrupt request of I
2
S ch.0 has been made.