CHAPTER 8: Interrupts
416 FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E
4.26 IRQ079/114 Batch Read Register (IRQxxxMON)
The IRQ079MON and IRQ114MON Registers can read out at once the interrupts (interrupts of USB ch.0
and ch.1, HDMI-CEC remote control reception ch.1 interrupt) assigned to exception no. 95 and no. 130
respectively.
Register configuration
bit
31
8
Field
Reserved
Attribute
R
Initial value
0x000000
bit
7
6
5
4
3
2
1
0
Field
Reserved
RCEC1INT
USB_INT
Attribute
R
R
R
Initial value
0
0
000000
Register function
[bit31:7] Reserved: Reserved bits
A reserved bit reads 0.
[bit6] RCEC1INT
Value
Description
0
There is no HDMI-CEC remote control reception ch.1 interrupt.
1
A HDMI-CEC remote control reception ch.1 interrupt has been made.