CHAPTER 8: Interrupts
FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E 397
4.10 IRQ021/022/023 Batch Read Register (IRQxxxMON)
The IRQ021MON to IRQ023MON Registers can read out at once the interrupts (WFG timer interrupts
and DTIF interrupts of MFT unit 0 to MFT unit 2) assigned to exception no. 37 to no. 39 respectively.
Register configuration
Register function
[bit31:4] Reserved: Reserved bits
A reserved bit reads 0.
[bit3:0] WAVEINT
There is no interrupt request of WFG timer 54 of the MFT unit corresponding to
the IRQxxxMON Register.
An interrupt request of WFG timer 54 of the MFT unit corresponding to the
IRQxxxMON Register has been made.
There is no interrupt request of WFG timer 32 of the MFT unit corresponding to
the IRQxxxMON Register.
An interrupt request of WFG timer 32 of the MFT unit corresponding to the
IRQxxxMON Register has been made.
There is no interrupt request of WFG timer 10 of the MFT unit corresponding to
the IRQxxxMON Register.
An interrupt request of WFG timer 10 of the MFT unit corresponding to the
IRQxxxMON Register has been made.
There is no interrupt request of the DTIF (motor emergency stop) of the MFT unit
corresponding to the IRQxxxMON Register.
An interrupt request of the DTIF (motor emergency stop) of the MFT unit
corresponding to the IRQxxxMON Register has been made.
See Table 3-1 and Table 3-2 for the relationship between exception no. and interrupt.