CHAPTER 8: Interrupts
414 FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E
4.24 IRQ076/077/111 Batch Read Register (IRQxxxMON)
The IRQ076MON, IRQ077MON and IRQ111MON Registers can read out at once the interrupts
(interrupts of A/D converter unit 0 to unit 2) assigned to exception no. 92, no. 93 and no. 127 respectively.
Register configuration
Register function
[bit31:5] Reserved: Reserved bits
A reserved bit reads 0.
[bit4:0] ADCINT
There is no range comparison result interrupt request of the A/D converter unit
corresponding to the IRQxxxMON Register.
A range comparison result interrupt request of the A/D converter unit
corresponding to the IRQxxxMON Register has been made.
There is no conversion result comparison interrupt request of the A/D converter
unit corresponding to the IRQxxxMON Register.
A conversion result comparison interrupt request of the A/D converter unit
corresponding to the IRQxxxMON Register has been made.
There is no FIFO overrun interrupt request of the A/D converter unit
corresponding to the IRQxxxMON Register.
A FIFO overrun interrupt request of the A/D converter unit corresponding to the
IRQxxxMON Register has been made.
There is no scan conversion interrupt request of the A/D converter unit
corresponding to the IRQxxxMON Register.
A scan conversion interrupt request of the A/D converter unit corresponding to the
IRQxxxMON Register has been made.
There is no priority conversion interrupt request of the A/D converter unit
corresponding to the IRQxxxMON Register.
A priority conversion interrupt request of the A/D converter unit corresponding to
the IRQxxxMON Register has been made.
See Table 3-1 and Table 3-2 for the relationship between exception no. and interrupt.