CHAPTER 19: Programmable CRC
FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E 937
#7 and #8 Wait for the completion of computing. Check that LOCK of the PRGCRC_CFG register is "0"
and go to the next step.
#9 If you need to input other data, go to step #10. If not, go to step #11.
#10 If input/output format change is required for the next input/output data, go to step #5. If not, go to step #6.
#11 Read the PRGCRC_RD register to acquire the computing results.
#12 Finish controlling for input data transfer from CPU.