Page #107 background imageLoading...
Page #107 background image
System time
5.2 NTP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
107
5.2.3.1
ntp server
Description
With this command, you configure the connection to a server on the NTP client.
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call up the command with the following parameters:
ntp server{ipv4 <ip_addr> | fqdn-name <FQDN(100)>}[port<123,1025-
36564>][poll<seconds(64-1024)>]
The parameter has the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IPv4 address
-
ip_addr
Value for the IPv4 address of the time
server
Enter a valid IPv4 address
fqdn-name
Keyword for a domain name
-
FQDN(100)
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
port
UDP port of the time server
• 123
• 1025 … 36564
Default: 123
poll
Keyword for the time after which the
time of day is requested again
-
seconds
Value for the time in seconds
64 … 1024
For information on identifiers of addresses and interfaces, refer to the section "Addresses
and interface identifiers (Page 23)".
Result
The connection to a server is configured on the NTP client.
Further notes
You delete the connection to a server with the no ntp server command.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals