Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
178 Configuration Manual, 11/2014, C79000-G8976-C351-03
Syntax
Call up the command with the following parameters:
wlan hw-retries <1-60>
The parameter has the following meaning:
Parameters
Description
Values or range of values
1-60
Number of retries 1 ... 60
Default: 16
Result
The number of retries is specified.
Further notes
You display the setting with the show wlan advanced <wlan 0/X> command.
6.1.5.42
wlan max tx-power
Description
With this command, you specify the transmit power of the device. It may be necessary to
reduce the transmit power when using antennas to avoid exceeding the maximum legal
transmit power. Reducing the transmit power effectively reduces cell size.
Note
The maximum possible transmit power varies depending on the channel and data rate. For
more detailed information on transmi
t power, refer to the documentation "Characteristics
radio interface".
Using the show wlan basic command, check whether or not the current WLAN settings
violate the permitted transmit power restrictions (
TX Power Check) of the selected country.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals