EasyManuals Logo

Siemens SCALANCE W760 Configuration Manual

Siemens SCALANCE W760
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #146 background imageLoading...
Page #146 background image
Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
146 Configuration Manual, 11/2014, C79000-G8976-C351-03
6.1.5.6
no wlan ampdu
Description
With this command, you disable the sending of AMPDU data packets. If the function is
disabled, only AMPDU data packets can be received.
Requirement
The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
no wlan ampdu
Result
The sending of AMPDU data packets is disabled.
Further notes
You display the setting with the show wlan advanced-11n <wlan 0/X> command.
You enable the function with the
wlan ampdu command (default setting).
See also
wlan ampdu (Page 145)
6.1.5.7
wlan ampdu bytes-limit
Description
With this command, you specify the maximum size of the AMPDU data packet in bytes.
Note
This command is
available only in access point mode.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals