Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
175
Syntax
Call up the command with the following parameters:
wlan frequency band { all | 2.4 | 5 }
The parameters have the following meaning:
Parameters
Description
Default setting
all
Both frequency bands are used.
WLAN1: 2.4 GHz
2.4
Frequency band 2.4 GHz
5
Frequency band 5.2 (4.9; 5.6; 5.8) GHz
Result
The frequency band for the WLAN interface is specified.
Further notes
You display the setting with the show wlan basic <wlan 0/X> command.
6.1.5.39
wlan guard interval (access point)
Description
With this command, you specify the send pause that must be kept to between two
transferred OFDM symbols.
Note
This command is available only in access point mode.
Requirement
The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals