Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
156 Configuration Manual, 11/2014, C79000-G8976-C351-03
6.1.5.18
wlan beacon interval (access point)
Description
With this command, you specify the interval at which the device sends beacons. Beacons
are packets that are sent cyclically by an access point to inform clients of its existence.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan beacon interval <ms(40-1000)>
The parameter has the following meaning:
Parameters
Description
Values or range of values
ms
Length of the interval in milliseconds
(ms).
40 ... 1000
Default: 100
Result
The interval is specified.
Further notes
You show the set interval with the show wlan advanced <wlan 0/X> command.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals