Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
319
Further notes
You delete the details of an SNMP group with the no snmp notify command.
You display the configured SNMP notifications with the
show snmp notif command.
You display the configured SNMP target addresses with the
show snmp targetaddr
command.
7.4.2.13
no snmp notify
Description
With this command, you delete the details of the SNMP notifications.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp notify <NotifyName>
The parameters have the following meaning:
Parameter
Description
Range of values / note
NotifyName
Name of the notification
max. 32 characters
Result
The details of the SNMP notifications are deleted.
Further notes
You change the details of an SNMP group with the snmp notify command.
You display the configured SNMP notifications with the
show snmp notif command.
You display the configured SNMP target addresses with the
show snmp targetaddr
command.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals