Security and authentication
10.2 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
371
Syntax
Call up the command with the following parameters:
wlan security ap-radius-authenticator reauth-interval <s(60-43200)>
The parameter has the following meaning:
Parameters
Description
Values or range of values
s
Lifetime in seconds 60 s ... 43200
Default: 3600
Result
The lifetime is configured.
Further notes
You display the setting with the show wlan security ap-radius-authenticator command.
You configure the local time management with the
wlan security ap-radius-authenticator
reauht-mode
command.
See also
wlan security ap-radius-authenticator reauth-mode (Page 371)
show wlan security ap-radius-authenticator (Access Point) (Page 361)
10.2.4.9
wlan security ap-radius-authenticator reauth-mode
Description
With this command, you specify who decides the time before the clients are forced to
reauthenticate.
Note
This command is available only in access point mode.
Requirement
You are in the WLAN Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-wlan)#

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals