Security and authentication
10.2 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
397
10.2.6.10
vap communication with ethernet (access point)
Description
With this command, you specify that the client can communicate via the Ethernet interface.
Note
This command is avail
able only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
vap communication with ethernet
Result
The communication option is enabled.
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
You disable the function with the
no vap communication with ethernet command.
See also
no vap communication with ethernet (access point) (Page 398)