Network protocols
7.1 IPv4 protocol
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
268 Configuration Manual, 11/2014, C79000-G8976-C351-03
Syntax
Call up the command with the following parameters:
no ip route <gateway>
The parameter has the following meaning:
Parameter
Description
Range of values
gateway
Specifies the IP address of the gateway.
Specify a valid IP address.
Result
The entry is deleted.
Further notes
You configure an entry from the IP routing table with the ip route command.
You display the IP routing table with the
show ip route command.
7.1.2.7
dcp server
Description
With this command, you configure the read and write permissions for the DCP server and
enable it.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
dcp server {read-only|read-write}
The parameters have the following meaning:
Parameter
Description
Range of values / note
read-only
only reading is permitted on the DCP
server
-
read-write
reading and writing is permitted on the
DPC server
Default: read-write

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals