Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
170 Configuration Manual, 11/2014, C79000-G8976-C351-03
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan dtim <1-15>
The parameter has the following meaning:
Parameters
Description
Values or range of values
1-15
DTIM interval after which the collected pack-
ets are sent to the client.
1...15
Default: 1
Result
The DTIM interval is configured.
Further notes
You display the setting with the show wlan advanced <wlan 0/X> command.
6.1.5.33
wlan ssid-table edit (client)
Description
With this command, you change or delete an entry in the SSID list.
Note
This command is only available in the client mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan ssid-table edit <index (1-4)> {enable | disable| delete} [ssid]

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals