System time
5.3 SNTP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
111
Result
The current SNTP unicast configuration is displayed.
5.3.4
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.
5.3.4.1
sntp
Description
With this command, you change to the SNTP configuration mode.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
sntp
Result
You are now in the SNTP configuration mode.
The command prompt is as follows:
cli(config-sntp)#
Further notes
You exit the SNTP configuration modewith the end or exit command.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals