Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
187
Syntax
Call up the command with the following parameters:
vap wds-id <wds id>
The parameter has the following meaning:
Parameter
Description
wds id
WDS ID
The WDS ID can be a maximum of 32 characters long.
Result
The WDS ID for the VAP interface is set.
Note
WDS IDs longer than 32 characters are truncated at 32 characters.
Further notes
You display the setting with the show wlan vap <vap X 0/Y>command.
6.1.6.2
vap ssid (access point)
Description
With this command, you configure the SSID for the relevant VAP interface.
Note
This command is available
only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#