Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
141
6.1.5.1
wlan allowed channels
Description
This command specifies which of the permitted channels the device can use. A list of the
permitted channels is created.
Requirement
The "Allowed channels only" function is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan allowed channels{ all | none | {[add][del]} [ 2.4 | 4 | 5 ] <channels> }
The parameters have the following meaning:
Parameters
Description
all
All permitted channels are entered in the list.
none
Access point:
All channels except for the following channels are deleted:
Operative channel
Alternative DFS channel
If "Auto" is set for the channel, the list is deleted and the first valid
channel of the selected frequency band is applied.
Client:
The list is deleted and the first valid channel of the selected frequency
band is applied.
add
The channels located in the <channel> parameter are added to the list.
del
The channels located in the <channel> parameter are deleted from the
list.
2.4
Optional parameter. Use this parameter to specify the frequency band
from which you want to add one or more channels to the list.
4
Optional parameter. Use this parameter to specify the frequency band
from which you want to add one or more channels to the list.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals