Configuration
3.4 Configuration Save & Restore
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
79
Syntax
Call the command without parameters:
auto-save
As default the function is "enabled".
Result
The auto save function is enabled.
Further notes
You save changes to the configuration in the Trial mode with the write startup-config
command.
You disable the function with the
no auto-save command.
You can display the status of this function and other information with the
show device
information
command.
3.4.3.2
no auto-save
Description
With this command, you disable the auto save function.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no auto-save
Result
The auto save function is disabled. The Trial mode is activated.