Security and authentication
10.2 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
396 Configuration Manual, 11/2014, C79000-G8976-C351-03
10.2.6.9
no vap communication with own-vap (access point)
Description
With this command, you specify that clients logged on to the same SSID of an access point
cannot communicate with each other.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
no vap communication with own-vap
Result
The communication option on the same SSID of an access point is disabled.
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
You enable the function with the
vap communication with own-vap command.
See also
vap communication with own-vap (access point) (Page 395)

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
Product TypeWireless Access Point
Frequency Bands2.4 GHz, 5 GHz
Wireless StandardsIEEE 802.11a/b/g/n/ac
Number of Antennas2
Power Supply24 V DC
Operating Temperature-20°C to +60°C
Operating Voltage24 V DC
Protection ClassIP65
Antenna ConnectorsR-SMA
SecurityWPA2, WPA3

Related product manuals