EasyManuals Logo

Siemens SCALANCE W760 Configuration Manual

Siemens SCALANCE W760
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #418 background imageLoading...
Page #418 background image
Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
418 Configuration Manual, 11/2014, C79000-G8976-C351-03
Parameter
Description
trap
Client that sends the SNMP traps
faults
The device triggers an error. The error LED lights up.
all
All clients at once
Result
The setting deciding which messages of the device are not stored or forwarded is
configured.
Further notes
You display the status of the events and the clients with the show events config command.
You configure which of the various message types of the device will be stored or forwarded
with the
event config command.
11.1.14.6
severity
Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog } { info | warning | critical }
The parameters have the following meaning:
Parameter
Description
Range of values / note
mail
Specifies the threshold value for send-
ing system event messages by e-mail.
-
log
Specifies the threshold value for enter-
ing system event messages in the log
table.
-
syslog
Specifies the threshold value for enter-
ing system event messages in the
Syslog file.
-

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals