EasyManuals Logo

Siemens SCALANCE W760 Configuration Manual

Siemens SCALANCE W760
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
Configuration
3.1 System
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
52 Configuration Manual, 11/2014, C79000-G8976-C351-03
Syntax
Call up the command with the following parameters:
no interface{vlan<vlan-id(1-4094)>}
The parameters have the following meaning:
Parameter
Description
Values
vlan
Keyword for a VLAN connection
-
vlan-id
Number of the addressed VLAN
1 … 4094
Result
The logical interface is deleted.
Further notes
You configure an interface with the interface command.
You display the status and the configuration of the interfaces with the
show interfaces
command.
3.1.9.6
cli-console-timeout
Description
With this command, you enable the automatic logout and you configure the timeout setting
for the CLI.
Note
No automatic logout from the CLI
If the connection is not terminated after the set time, check the setting of the "keepalive"
function on the Telnet client. If the set interval is shorter than the configured time, the lower
value applies. You
have set, for example, 300 seconds for the automatic logout and the
"keepalive" function is set to 120 seconds. In this case, a packet is sent every 120 seconds
that keeps the connection up.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals