EasyManuals Logo

Siemens SCALANCE W760 Configuration Manual

Siemens SCALANCE W760
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #256 background imageLoading...
Page #256 background image
Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
256 Configuration Manual, 11/2014, C79000-G8976-C351-03
6.3.5.4
no name
Description
With this command, you reset the name for the MST region to the default value.
The default value is:
The MAC address of the device is configured as name.
Requirement
You are in the MSTP Configuration mode.
The command prompt is as follows:
cli(config-mst)#
Syntax
Call the command without parameters:
no name
Result
The name is reset to the default value.
Further notes
You configure the name of the MST region with the name command.
You display this setting and other information with the
show spanning tree mst
configuration
command.
6.3.5.5
revision
Description
With this command, you assign a revision number to the MST region.
Requirement
You are in the MSTP Configuration mode.
The command prompt is as follows:
cli(config-mst)#