Diagnostics
11.2 Syslog client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
424 Configuration Manual, 11/2014, C79000-G8976-C351-03
11.2.2.1
syslogserver
Description
With this command, you configure the Syslog server address.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
syslogserver {ipv4 <ucast_addr> | fqdn-name <FQDN(100)>} [<port(1-65535)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IP address
-
ucast_addr
Syslog server IPv4 Address Enter a valid IPv4 address.
fqdn-name
Keyword for a domain name
-
FQDN(100)
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
port
Serverport 1 .. 65535
Default: 514
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 23)".
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for the Syslog server are configured.
Further notes
You disable the setting with the no syslogserver command.
You can display the status of this function and other information with the
show events config
command.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals